Please use this identifier to cite or link to this item:
http://lib.kart.edu.ua/handle/123456789/33848Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Кустов, Віктор Федорович | - |
| dc.contributor.author | Єлізаренко, Андрій Олександрович | - |
| dc.contributor.author | Kustov, Viktor | - |
| dc.contributor.author | Yelizarenko, Andriy | - |
| dc.date.accessioned | 2026-10-19T16:59:31Z | - |
| dc.date.available | 2026-10-19T16:59:31Z | - |
| dc.date.issued | 2026 | - |
| dc.identifier.citation | Кустов В. Ф. Національні особливості радіочастотного поля залізниць України та вимоги до проєктування ЕМС систем СЦБ / В. Ф. Кустов, А. О. Єлізаренко. Збірник наукових праць Українського державного університету залізничного транспорту. 2026. Вип. 217. С. 337-360. | uk_UA |
| dc.identifier.issn | 1994-7852 (рrint); 2413-3795 (оnline) | - |
| dc.identifier.uri | http://lib.kart.edu.ua/handle/123456789/33848 | - |
| dc.description.abstract | UA: Оцінено інженерну відповідність нормованих ДСТУ EN 50121-4 рівнів несприйнятливості апаратури СЦБ фактичному радіочастотному середовищу залізниць України. Розглянуто штатний і сторонній VHF-радіозв'язок у смузі 150–156 МГц і CB-діапазон 27 МГц (Citizens Band, цивільний діапазон радіозв'язку). Показано, що документально підтверджені для України потужності VHF-передавачів можуть формувати розрахункові рівні поля, вищі за базовий випробувальний рівень 10 В/м. Для 27 МГц запропоновано аналізувати не лише зовнішнє поле, а і синфазні кондуктивні завади, індуковані на кабельних портах. Запропоновано трирівневий підхід: Національний додаток має конкретизувати характерні електромагнітні впливи; галузеві технологічні норми проєктування – правила EMC-зонування, рознесення, прокладання кабелів, екранування, заземлення, захисту портів і верифікації рішень з урахуванням функціональної безпечності; регламент експлуатації – обмеження для персональних радіозасобів і перевірку цілісності засобів екранування. | uk_UA |
| dc.description.abstract | EN: An engineering assessment is conducted to evaluate the correspondence between the radio-frequency immunity levels specified by EN 50121-4 and the actual electromagnetic environment of Ukrainian railways. This assessment covers the railway VHF band at 150–156 MHz, including portable, mobile, and stationary transmitters, as well as the 27 MHz CB band (Citizens Band) as a scenario in which radiated electromagnetic fields can induce common-mode conducted disturbances on signalling and interlocking (SCI) cables and equipment ports. The analysis demonstrates that documentary-confirmed transmitter power levels currently authorized for use in Ukraine can generate calculated field strengths exceeding the basic immunity test level of 10 V/m at characteristic distances. For the 27 MHz band, the assessment emphasizes the analysis not only of radiated fields but also of common-mode conductive interference induced on cable ports through the mechanisms of antenna coupling and grounding path impedance. The frequency-dependent immunity levels established in EN 50121-4 are examined as methodological precedents for scenario-oriented national adaptation. A three-level approach is proposed: (1) a National Annex should identify characteristic electromagnetic influences and test scenarios specific to Ukrainian railway infrastructure; (2) sectoral EMC design rules should establish zoning principles, separation distances, cable routing, shielding, bonding, grounding, port protection and verification procedures with consideration of functional safety; and (3) operational regulations should impose restrictions on personal RF transmitters used in proximity to open apparatus and require periodic verification of passive shielding measures with regard to functional safety and signal integrity throughout the equipment lifecycle. | - |
| dc.publisher | Український державний університет залізничного транспорту | uk_UA |
| dc.subject | електромагнітна сумісність | uk_UA |
| dc.subject | СЦБ | uk_UA |
| dc.subject | радіочастотне поле | uk_UA |
| dc.subject | EN 50121-4 | uk_UA |
| dc.subject | технологічний радіозв'язок | uk_UA |
| dc.subject | CB-діапазон | uk_UA |
| dc.subject | рівень несприйнятливості | uk_UA |
| dc.subject | EMC-проєктування | uk_UA |
| dc.subject | Національний додаток | uk_UA |
| dc.subject | electromagnetic compatibility | uk_UA |
| dc.subject | railway signalling systems | uk_UA |
| dc.subject | radio-frequency field | uk_UA |
| dc.subject | EN 50121-4 | uk_UA |
| dc.subject | VHF railway radio | uk_UA |
| dc.subject | CB band | uk_UA |
| dc.subject | immunity level | uk_UA |
| dc.subject | EMC design | uk_UA |
| dc.subject | National Annex | uk_UA |
| dc.title | Національні особливості радіочастотного поля залізниць України та вимоги до проєктування ЕМС систем СЦБ | uk_UA |
| dc.title.alternative | National features of the radio frequency field of Ukrainian railways and EMC requirements for the design of signaling and interlocking systems | uk_UA |
| dc.type | Article | uk_UA |
| Appears in Collections: | Випуск 217 | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Kustov.pdf | 492.82 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.